PG. 6 #8402 QC-40 INSTALLATION & MAINTENANCE MANUAL
2.0 — Control Set-Up and Operation
MICROPROCESSOR CONTROL
The Alto-Shaam
® Quickchiller includes a
microprocessor control panel which utilizes a menu
screen to guide the operator through all operation
mode sequences.
®
  
  
  
  
A
B
C
D
QUICK CHILL A
HOLD FOOD B
DEFROST FOOD C
PRINT REPORT D
CE
0
CHILLING or HOLDING
1. LOAD FOOD. IF A PRINTOUT IS REQUIRED OR
IF "AUTO-CHILLING" INSERT PRODUCT PROBES.
2. SELECT MODE OF OPERATION "A" OR "B" FROM
THE MENU, THEN FOLLOW PROMPTS.
DEFROSTING
1. REMOVE FOOD FROM UNIT.
2. SELECT MODE "C" FROM MENU, THEN
FOLLOW PROMPTS.
NOTES:
THE UNIT WILL PERIODICALLY AUTO-DEFROST
WHILE HOLDING.
REFER TO THE OPERATION MANUAL FOR MORE
DETAILED INFORMATION.
...................
.....................
...............
.................
MENU SCREEN
MAIN MENU SHOWN
CONTROL KEYBOARD
QUICK REFERENCE OPERATION GUIDE
Fig. 2.1.3
2.3 START-UP TEST
2.3.1 With the chiller door closed, test the door
buzzer and door switch by entering the hold
cycle. Press "B" on the keyboard when the
Main Menu screen appears on the display.
The compressor will become audible. After a
period of 60 seconds, open the unit door. A
buzzer should sound and the display will
prompt the operator to close the door.
2.3.2 Close the door and allow the unit to operate
for approximately 10 minutes. Verify the
operating time with the timer which appears
in the upper right-hand corner of the Hold
Mode display screen. If the timer does not
indicate the correct amount of time, begin the
SET-UP procedure once again.
2.3.3 With the food probe(s) remaining in the
appropriate holder (no product) verify a
decrease of the temperatures appearing in the
display. The temperatures displayed should
start at the approximate room temperature and
decrease from that point. If any of the
temperatures displayed are above 120°F
(49°C), considerably above normal room
temperature, contact the Alto-Shaam Service
Department.
2.3.4 Following the 10 minute test operation period,
press "D" on the keyboard to exit the hold
mode. Open the unit door and make certain
the interior walls of the unit are cold.
2.4 SEQUENCE OF CONTROL OPERATION
2.4.1 Refer to Tables 2.4.1 and 2.4.2 for an overview
of control operations. For more information,
refer to booklet No. 265, Quickchiller Operation
Procedure Guidelines.