#8402 QC-40 INSTALLATION & MAINTENANCE MANUAL PG. 5
2.1 START-UP PROCEDURES
2.1.1 Place the branch circuit breaker (main
panel) in the ON position. Then place the
Quickchiller circuit breaker in the ON
position.
2.1.2 The Main Menu screen must appear on
the Control display (see figure 2.1.3). If
the Main Menu screen appears, skip
Sections 2.1.3 thru 2.1.5 and proceed with
SET-UP per Section 2.2. If the Main Menu
screen does not appear, proceed with
Section 2.1.3.
2.1.3 The control display will show "SYSTEM
INITIALIZED" and an audible alarm will
sound for 30 to 60 seconds. Leave the
unit alone for two (2) minutes.
2.1.4 Turn the Quickchiller circuit breaker OFF.
Leave the unit OFF for 30 seconds.
2.1.5 Turn the Quickchiller circuit breaker ON
again. The Main Menu screen on the
display should now appear.
2.2 SET-UP
2.2.1 Make certain the main menu appears on
the control display (LCD) when power is
supplied to the unit.
2.2.2 Access the Password screen: Press and
hold the "0" button on the keyboard for a
period of 5 seconds. When the Password
Entry screen is in view, enter the password
number on the numerical keyboard.
PASSWORD
5588744
Following password entry, press "D" on
the keyboard to access the User Setting
Menu screen. If the wrong password
number is entered in error, "Access
Denied" will appear in the display. If it
remains in the display longer than 60
seconds, the locked control panel cover
must be opened and the yellow reset
button pressed ONCE. Relock the control
panel and enter the correct password to
gain access to the User Setting Menu
screen.
2.2.3 Select option "B" and set the
correct time and date.
Following entry, press "C," immediately
followed by "D" to return to the Main
Menu screen. (
FOR ADDITIONAL
INFORMATION SEE BOOKLET NO
. 265,
Quickchiller Operating Procedure Guide,
SECTION 7.0 USER SET-UP.)
2.2.4 Press and hold the "1" button on the
keyboard for a period of five (5) seconds.
The Software Version screen will appear.
Quickchiller Model QC-40 must appear. If
Model QC-40 appears, proceed with
Section 2.3. If Model QC-40 does not
appear, proceed with Sections 2.2.5
through 2.2.7.
2.2.5 Press and hold zero (0) button again
until Password Entry screen appears.
Enter password number on the
numerical keyboard.
Press "D" Button to access Set-up Menu
Screeen.
2.2.6 Select option "C" and set correct Chiller
Model to "QC-40" using the "C" button.
Following entry, press "D", and press "D"
again to return to Main Menu screen.
2.2.7 The QC-40 is now ready for operation.
2.0 — Control Set-Up and Operation
FOR A COMPLETE AND COMPREHENSIVE GUIDE
TO THE OPERATION OF THE QUICKCHILLER SEE
BOOKLET NO. 265,
QuickchillerOperating Procedure Guide
Password
5588744
NOTE: BACK-UP BATTERY POWER
The Quickchiller control back-up battery is
fully charged prior to Quickchiller shipment
and will maintain control memory for
approximately fourteen (14) days.
NOTE: TWENTY
-FOUR (24) HOUR TIME OR
MILITARY TIME IS REQUIRED
.
1:00 PM = 1300 M
ILITARY TIME
Password
16021892