#8402 QC-40 INSTALLATION & MAINTENANCE MANUAL PG. 3
1.5 RECEIPT AND UNPACKING
Upon receipt of the Alto-Shaam
® Quickchiller,
note any crate markings for special instructions
and check for crate damage. IMMEDIATELY
notify the carrier if there appears to be damage
to the equipment. The chiller is shipped from
the factory, securely fastened to a single shipping
pallet and protected by an external wrapping.
Carefully remove all external wrappings and
other protective coverings. If all is in order,
discard crating materials.
1.6 INSTALLATION
Prior to moving the Quickchiller to the
installation site, check the dimensions of doors,
passageways, and ceiling heights in the areas
through which the cabinet must be moved. Also
check the turning radius if the cabinet must be
moved around an existing structure.
Note: In certain instances, it may be necessary
to remove doors and door hardware to
negotiate tight spaces.
1.6.1 SITE SELECTION: Position the Quickchiller
to allow sufficient air ventilation through the
condensing unit(s). Rear of unit should be no
closer than 6" to any wall or structure.
Avoid installing the chiller immediately
adjacent to fryers, charbroilers, or any other
equipment producing grease laden air; heat
producing equipment such as ovens and
ranges; and steam discharging equipment
such as steamer ovens and kettles.
Allow sufficient front clearance for
serviceability and for easy maneuvering of
food trolleys in and out of the cabinet.
1.6.2. INSTALLATION REQUIREMENTS: Install
the Quickchiller on smooth and level floor
surface. The unit must be leveled with the
SLIDE-IN PAN RACK inside the cabinet.
Use the adjustable cabinet legs to level the
unit.
Adjust from front-to-back and from side-to-
side to evenly distribute the cabinet weight
and avoid pulling the cabinet alignment out
of square.
After leveling the cabinet, check the height
relationship of the (
OPTIONAL) base trolley to
the slide-in pan rack inside the cabinet.
Adjust Quickchiller height as needed.
1.6.3 DOOR SEAL: Check the door gasket to make
certain it is sealing properly and that the
gasket provides an even and positive seal
around the entire door frame.
1.6.4 DRAIN HOSE: Unit includes an evaporative
base condensing unit. No plumbing is
required for condensate drainage. Refer to
Section 5.5 for cleaning instructions.
1.6.5 REMOTE CONDENSING UNIT GUIDELINES
Installation must be performed by certified
and authorized refrigeration service
personnel or warranty is void.
Interconnecting liquid and suction line sizes
for Quickchillers are as follows:
Separation distance between the Quickchiller
and condensing units must not exceed fifty
(50) feet with zero (0) lift. Liquid line lift
(Quickchiller elevation above that of
condensing unit) reduces allowable
separation distance significantly.
Satisfactory refrigerating capacity is possible
with condenser entering air temperatures
below 115°F.
Insulate both suction and liquid lines.
Suction lines should be pitched down 1/2" in
10' of run in the direction of flow. A "P" trap
(closely) connected) is required for vertical
risers greater than 3 feet in elevation.
1.0 — General Information and Installation
DRAIN
FIG. 1.6.4 PLUMBING: MODEL QC-40
QUICKCHILLER CONDENSING LIQUID LINE SUCTION LINE
MODEL UNIT SIZE SIZE
QC-40R Both 1/4" 3/8"
QC-50R Large 3/8" 7/8"
Small 3/8" 5/8"
QC-100R Both 3/8" 7/8"