Alto-Shaam QC-50 Operations Instructions Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 29
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
2.7 SHUT-DOWN PROCEDURE
The Quickchiller can be shut-down at the end of
the production day whenever any menu screen
which includes STOP=D is displayed.
Before starting unit shut-down, make certain all
product has been removed from the unit. Press
"D" on the keyboard to begin shut-down.
The unit will display a Stop Prompt screen as a
safeguard against accidental shut-down.
Press "C" on the keyboard to continue shut-
down. The Main Menu Screen will appear in
the display.
MAIN MENU SCREEN
The Quickchiller will be ready for start-up as
required and will be fully operational after
allowing 40 minutes to pre-chill before resuming
operations with product.
For prolonged periods of shut-down, thoroughly
clean and sanitize the interior and exterior of the
unit with a mild detergent diluted in warm
water. Maintain the Quickchiller circuit breaker
and branch circuit breaker (Main Panel) in their
ON positions to preserve control data memory. If
power is terminated for more than fourteen (14)
days, and control data memory is lost, refer to
Control Set-Up and Operation, Section 2.0.
2.8 HARDWARE NOTES
NOTE: Refer to Operation and Procedure Guide, Section 9.0.
SERIAL PRINTER:
The printer MUST have an internal buffer of at least 1K
bytes. Since the printer must be able to maintain the same
pace as the control, and there is no printer handshaking,
printers with smaller buffers simply cannot keep up. The
printer must also conform to RS-232 standards and must be
able to print using only the TX and GND lines (i.e., without
hardware handshaking or software handshaking
(XON/XOFF). Nearly all serial printers can print without
handshaking. The printer should be connected to the
control with a NULL serial cable.
RECOMMENDED:
Star Micronics PN# DP-8340 FM
Alto-Shaam Serial Printer & Cable Package PN#14218
PARALLEL PRINTER:
Any EPSON, IBM PRO-PRINTER or compatible is acceptable.
The internal buffer should be at least 1K byte. Most of the
newer printers have at least this amount or more. A standard
printer cable is required. It is not necessary to use a printer
with 24 pins or special graphic capabilities. Alto-Shaam
Parallel Printer Cable (part number 14709) is recommended to
connect parallel printer to Quickchiller control .
DIP SWITCH:
The dip-switch is located on the CPU board. It is read by the
software each time the main menu is entered. Changing the
settings while at the main menu will not effect a change until
the main menu is exited and reentered.
When taking advantage of the special feature program options,
we strongly recommend
individuals with an electronics
background to properly locate
and change dip-switch position.
Refer to Operation and Procedure
Guide, Section 8.1.
#8400 Installation & Maintenance Manual - Pg. 10
2.0 Controls, Operation and Start-Up
SWITCH
NUMBER
FUNCTION OFF ON
1 Language ENGLISH SPANISH
2 Reserved ——
3 Reserved ——
4 On-Line Print NO YES
5 Reserved ——
FIG. 2.8 - CPU BOARD
(PARTIAL VIEW)
DIP-SWITCH LOCATION
UPPER: 40F (DONE)
MID: 38F (DONE)
LOWER: 36F (DONE)
HOLD: 38F STOP=D
ARE YOU SURE?
YES . . . . . . . . . . . . . . . . . . . .C
NO . . . . . . . . . . . . . . . . . . . .D
QUICK CHILL . . . . . . . . . . . A
HOLD FOOD . . . . . . . . . . . . B
DEFROST UNIT . . . . . . . . . . C
PRINT REPORT . . . . . . . . . . D
NOTE: The condensing unit(s) will shut
off immediately, bypassing the low
pressure switch. No pump-down
will occur.
1 2 3 4 5
DIP-SWITCH
BUZZER
Page view 11