#8400 • 5/2002®QC-50PROCESSING REFRIGERATION SYSTEMINSTALLATIONandMAINTENANCEMANUALW164 N9221 Water Street ●P.O. Box 450 ●Menomonee Falls, Wisconsin 5
#8400 Installation & Maintenance Manual - Pg. 82.0 — Control Set-Up and OperationTable 2.4.1CONTROL MODE OVERVIEWMode Operation DescriptionRefrig
2.5 MAIN MENUThe main menu is the starting point for allfunctions of the Quickchiller. This includesstarting the hold, defrost, and chill cycles; re
2.7 SHUT-DOWN PROCEDURE The Quickchiller can be shut-down at the end ofthe production day whenever any menu screenwhich includes STOP=D is displayed.
AT-A-GLANCEQC-50 CONTROL SETTINGSPRINTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Printer Interface = SerialBaud Rate
DESCRIPTION QUAN. PT. NO.72" (1829mm) Food Probe Assembly 3 PR-3850Cold Tube Sensors, 1-3/4" 3 SN-3888Sensor Mounting Block 1 BK-22636ITEM
#8400 Installation & Maintenance Manual - Pg. 13ITEM:MODEL:DATE: REV: DWN BY: SCALE:MENOMONEE FALLS, WISCONSIN, U.S.A.®CPU ENCLOSURE #15034Quickch
1-21-2RIGHT HAND FANSRIGHT HAND FANS3-43-45-65-6L1L1I/OI/OCABLECABLEA2425A2425SOLID-STATE RELAYSOLID-STATE RELAYCRYDOMCRYDOMOUTPUTOUTPUTSC-20SC-20BUSS
#8400 Installation & Maintenance Manual - Pg. 153.0 — Parts Identification3.4 — QC-50 - REFRIGERATION PARTS LISTITEM DESCRIPTION QUAN. PT. NO.1.
4.1 INTRODUCTIONThe relays, which control the compressors, fans,solenoids, and heaters, can be individually controlledby the microprocessor control se
4.3 CONDENSING UNITSThe condensing units operate only when the system isin a cooling mode and the food storage compartmentrequires a decrease in tempe
Table of Contents - QC-501.0 GENERAL INFORMATION & INSTALLATION page1.1 Introduction ...11.2 Scope of the Manual ...
4.5 TROUBLE-SHOOTING GUIDELINES - CONTROL#8400 Installation & Maintenance Manual - Pg. 18PROBLEMAlphanumeric display is blank.If power is connect
#8400 Installation & Maintenance Manual - Pg. 194.0 — Diagnostic and Repair Procedure — REFRIGERATIONThis chart is provided for the assistance o
#8400 Installation & Maintenance Manual - Pg. 203-4RIGHT HAND FANSL1 5-6 5-6 3-4L1 1-2LEFT HAND FANS1-2HEATERS1 32L1 5HEATERS4 6L1COMPRESSORNC L1S
#8400 Installation & Maintenance Manual - Pg. 21
#8400 Installation & Maintenance Manual - Pg. 22
#8400 Installation & Maintenance Manual - Pg. 23
#8400 Installation & Maintenance Manual - Pg. 24
#8400 Installation & Maintenance Manual - Pg. 25
5.1 INTRODUCTIONTo insure trouble free operation and thehighest level of sanitation control,periodic cleaning and maintenance isrequired. The mainten
TRANSPORTATION DAMAGE and CLAIMSAll Alto-Shaam equipment is sold F.O.B. shipping point,and when accepted by the carrier, such shipmentsbecome the pro
1.1 INTRODUCTIONThe Alto-Shaam® Quickchiller is a processingrefrigeration system designed to rapidly and uniformlycool hot foods through the "chi
#8400 Installation & Maintenance Manual - Pg. 21.0 — General Information and InstallationITEM: Quickchiller Assembly DrawingMODEL: QC-50 Quickchi
#8400 Installation & Maintenance Manual - Pg. 31.0 — General Information and InstallationITEM: Quickchiller Assembly Drawing - RemoteMODEL: QC-50
1.5 RECEIPT AND UNPACKINGUpon receipt of the Alto-Shaam® Quickchiller, noteany crate markings for special instructions andcheck for crate damage. IMM
1.6.6 ELECTRICAL: The Quickchiller must beinstalled by a qualified electrician. Thisappliance must be branch circuit protectedwith proper ampacities
2.1 START-UP PROCEDURES2.1.1 Place the branch circuit breaker (mainpanel) in the ON position. Then place theQuickchiller circuit breaker in the ONpos
#8400 Installation & Maintenance Manual - Pg. 72.0 — Control Set-Up and OperationMICROPROCESSOR CONTROLThe Alto-Shaam® Quickchiller™ includes ami