RELAY BOARD
The relay board (Figure 11) is mounted in a metal enclosure with a metal or lexan cover over it. For the
QC-3 it is located behind the front grille, mounted to the left of the compressor and can be slid out for
servicing. For the QC-20 it is located behind the CPU enclosure, laying flat and can be slid out for servicing.
For the QC-40 it is located behind the lower grille, mounted to the left of the compressors and can be slid
out for servicing. For the QC-50 it is located behind the upper grille, to the left of the compressors and can
be accessed by removing the metal cover. For the QC-100 it is located inside the locked CPU enclosure at the
top of the enclosure.
The relay board has 6 (F1-F6) 2A fuses to protect the fans. There are 6 (F7-F12) 4A fuses to protect the
defrost heaters in all Quickchillers except the QC-40 which uses 6.3 Amp fuses. All units use 2 (F13-F14)
300MA fuses to protect the refrigerant solenoids and 1 (F14) 250MA fuse to protect the compressor relays. The
2 (F16-F17) 1A fuses protect the 24 VAC power to the CPU board.
5.
Figure 11
FAN FUSES
DEFROST
HEATER
FUSES
COMPRESSOR
FUSE
SOLENOID
FUSES
HEATER DEFROST
RELAYS 14VDC
POWER LED
EVAPORATOR FANS
LEFT
RIBBON CABLE
CONNECTOR
DOOR
SWITCH
BEEPER 5DVC
TO CPU BOARD
24VAC
TO CPU BOARD
24VAC
FROM
TRANSFORMER
CPU
POWER FUSES
EVAPORATOR FANS
RIGHT
DEFROST
HEATERS
REFRIGERANT
SOLENOID
RIGHT LEFT
COMPRESSORS