Alto-Shaam QC-40 User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
QUICKCHILLER SET-UP
Since all Quickchillers use the same microprocessor, they
must be configured for each specific model. The set-up is
completed at the factory, however, if the unit is unplugged for
more than 14 days, the microprocessor will lose the factory set
memory and revert back to a default setup. The default is
always specific to the model QC 50.
The Main Menu screen must appear on the control
display. To access the Password screen, press and hold the
0 key on the key board for 5 seconds. When the Password
screen is in view, enter the password 5588744 using the
control keyboard (Figure 3).
After entering the password on the Password screen, press
the D key on the keyboard to access the User Setting screen.
Press and hold the "1" button on the keyboard for a period of five (5)
seconds. The Software Version screen will appear. The Quickchiller
model number must appear.
Press and hold the "1" button on the keyboard for a period of five (5) seconds. The Software Version screen will
appear. The Quickchiller model number must appear.
If the model number does not appear, press and hold zero (0) button again until Password Entry screen appears.
Enter password 16021892 and press "D" button to access Set-up Menu Screen. Select option "C" and set correct chiller
model number using the "C" button. Following entry, press "D", and press "D" again to return to Main Menu screen.
NOTE: If the wrong password number is entered in error, ACCESS DENIED (Figure 4) will appear in the
display, an alarm will sound for 10 seconds, and the Main Menu screen will reappear. If this
situation occurs, press and hold the 0 key for 5 seconds and reenter the correct password.
SETTING TIME, DATE & OPTIONS
When the User Setting screen (Figure 5) appears on the
control display, push the B key on the keyboard to access
the time and date screen (Figure 6). The time and date are
very important particularly if a printer is used since
incorrect time and date settings will impact the printout.
NOTE: TIME MUST BE ENTERED AS 24 HOUR,
MILITARY TIME (HH:MM:SS).
After the time and date have been set, press the C key
to return to the User Setting screen. After the User Setting
screen appears, press the C (Miscellaneous) key to change
the following options. Press A to scroll to the next screen.
TEMPERATURE UNITS: Allows the user to choose
between Celsius and Fahrenheit.
KEYBOARD BUZZER: Allows the user to turn tone sound ON or OFF.
AUTOMATIC DEFROST: Allows the user to turn the Auto-Defrost ON or OFF.
DEFROST TIME: Allows the user to set the maximum minutes for the defrost cycle.
NOTE: DEFAULT IS SET FOR 20 MINUTES
AFTER ALL OPTIONS HAVE BEEN SELECTED, PRESS “D” TO EXIT AND RETURN TO THE USER SETTING SCREEN.
SETTING SET POINTS
From the user screen, press theA (Set Point) key to access the Numeric Setting screen (Figure 7). All
set points are shown in Celsius and can only be changed within an allowable range. Any value entered
outside of this range will result in a warning buzzer and the value must be reentered. To reset any set point
to the factory default, push the CE key to show the default values for each set point and then key in the
Q-CHILLER CONFIGURE
PASSWORD: 5588744
Figure 3
PASSWORD ENTRY SCREEN
Figure 4
PASSWORD DENIED SCREEN
Figure 5
USER SETTING MENU SCREEN
Figure 6
TIME AND DATE SCREEN
ACCESS DENIED
Set Points . . . . . . . . . . . . A
Time and Date . . . . . . . . . B
Miscellaneous . . . . . . . . . C
Exit . . . . . . . . . . . . . . . . D
Enter Time and Date
01/17/01 08:33:48
A=Left C=Accept
B=Right D=Cancel
2.