Alto-Shaam QC-40 Service Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
1010 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 26
It is VERY important to decalcify the oven, particularly in areas
with extremely hard water.
PERFORM ONCE A MONTH
in addition to the daily steam generator flush.
WITH THE OVEN AT ROOM TEMPERATURE
1. Begin decalcification with the power switch in the OFF position.
2. Rotate the Steam Generator Drain Cap until water begins to flow from the four holes in the cap. In
approximately 20 to 60 seconds, a sufficient quantity of water will have drained from the steam generator so
that the drain cap can be completely removed.
3. As the water continues to flow from the
generator, it will have a milky or cloudy
appearance, which indicates deposits in
the generator system are beginning to
flush out. Let the water continue to
drain until the flow completely
subsides. Replace the Steam Generator
Drain Cap by turning it clockwise
until there is a slight resistance.
4. Unscrew the cap from the
Decalcification Port . With the
use of a funnel, pour one-half gallon
(c. 2 liters) of distilled white vinegar
into the Decalcification Port.
5. Replace the cap on the Decalcification Port and tighten securely.
Scalding water will erupt from the Decalcification
Port
when the oven is operating unless the cap
is replaced and tightened.
COMBITHERM
®
DECALCIFICATION
CONTROL
OPTION
CONTROL
OPTION
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 44 45

Comments to this Manuals

No comments