1010 MARINE COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 8
WATER SUPPLY
CONNECT TO POTABLE (DRINKABLE) COLD WATER ONLY
WATER PRESSURE REQUIREMENTS: MINIMUM 30 PSI (2 BAR)
MAXIMUM 90 PSI (6 BAR)
Flush the water line at the installation site before connecting the oven to the water supply. A shut-off valve and
approved back-flow preventer must be installed when connecting the oven to the cold water intake. The water
supply line must be a minimum of 3/4-inch (NPT) (19mm). A hose connector is supplied for flexible hose
connection to the COLD water source. Connected water should test at hardness level of 5 to 9 grains per gallon
(85 to 154 ppm). A water filtration system is recommended if the water supply is between 5 and 9 gpg of
hardness. If water tests over 18 gpg of hardness (344 ppm), the
installation of a water softener to maintain oven function is strongly
recommended.
PIPE SEALING TAPE (TEFLON®) MUST BE USED
AT ALL CONNECTION POINTS.
The use of a pipe sealing compound is not recommended.
THE SHUT-OFF VALVE MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.
The hand shower spray hose is installed adjacent
to the cold water intake connection. A ball valve
is installed on the oven for hose connection to the
COLD water source. Assemble the washer and
the flexible hose on the ball valve and hang the
spray handle on the holder previously installed
on the oven.
Alto-Shaam now offers an improved water filtration system for
Combitherm®. The CombiGuard triple-guard water filtration
system filters dirt, sediment, and other debris as small as 1/2
micron. This system also significantly reduces chlorine content to
protect against corrosive chlorine compounds. CombiGuard
improves equipment efficiency, reduces service requirements and
extends the life of the Combitherm. Filtration system includes one
filter cartridge. Additional cartridges (FI-26356) can be
purchased separately.
COMBITHERM
®
INSTALLATION
WATER
COLD WATER DRINKING QUALITY
INDIRECT WASTE PIPE WITH AIR GAP: 1-1/2" NPT
INLET: 3/4" NPT LINE PRESSURE: 30 to 90 psi
2 to 6 bar
CHLORINE: less than 0.8 ppm CHLORIDE: less than 70 ppm
HARDNESS: 5 to 9 gpg PH R ANGE: 7.0 to 9.0
85 to 154 ppm
WATER SOFTENER SHOULD BE UTILIZED
IN HARD WATER AREAS
.
ITEM FI-23014
Page view 9