COMBITHERM GAS INSTALLATION AND MAINTENANCE MANUAL 6011ML
PG.2
1.3 VENTILATION REQUIREMENTS
A steam ventilation hood is mandatory for the operation of the oven. The ventilation hood must be installed
in accordance with local building codes for steam exhaust and must protrude 12-inches to 20-inches
(300mm to 500mm) over the front side of the oven. A grease filter must be located in the protruding area of
the hood. Grease filters should be thoroughly cleaned on a regular basis following manufacturer's
instructions. Ventilation hoods must ensure an adequate amount of incoming air during operation and must
be operated whenever the combination oven/steamer is used in order to avoid the accumulation of
condensation in the hood area. See the section titled Gas Exhaust.
1.4 POSITIONING ON SITE
Lift the oven from the pallet with a fork
lift or pallet lift truck positioned at the
front of the oven. For damage protection,
the use of two wooden boards, placed
between the bottom of the oven and the
lifting forks, is strongly recommended.
Stand the oven in a level position. Use the
adjustable feet to overcome an uneven
floor and ensure that the unit is level.
It is strongly recommended that table top
models be mounted on a factory supplied
stand or a stand that is stable, open, level,
and non-combustible. Recommended height
is 23-inches (584mm).
Adjust the height of floor models for
smooth access of the trolley or cart.
Ensure that the unit is level, right-to-left
and back-to-front. When positioning the
oven, observe the minimum space allocation
requirements shown.
To insure proper operation, the installation of this oven must be completed
by qualified technicians in accordance with the instructions provided in
this manual. Failure to follow the instructions provided may result in
damage to the oven, building, or cause personal injury to personnel.
1.5 INSTALLATION CODES & STANDARDS
The following codes and standards are required for installation of this oven:
AIR SUPPLY, ELECTRICAL CONNECTIONS, WATER CONNECTIONS,
GAS CONNECTIONS, GAS EXHAUST, AND WASTE WATER DISCHARGE.
Installation must comply with local codes required for gas appliances. In the absence of local
codes, installation must comply with the National Fuel Gas Code, ANSI Z223.1 (latest
edition). In Canada, the appropriate code is the Natural Gas Installation Code,
CAN/CGA-B149.1 or the Propane Installation Code, CAN/CGA-B. Adherence to code by a qualified installer
is essential for the following: Gas Plumbing, Gas Appliance Installation, Commercial Cooking Ventilation,
Water and Plumbing, and OSHA Regulations. The installation surface must be heat resistant and non-
combustible (unable to burn). See your local codes or the National Fuel Gas Code for the definition of
combustible and non-combustible construction.
COMBITHERM® GAS INSTALLATION
MODEL
610MLGAS
1010MLGAS
714MLGAS
1020MLGAS
1218MLGAS
2020MLGAS
NET WEIGHT
377 lb (171 kg)
490 lb (222 kg)
528 lb (239 kg)
573 lb (260 kg)
666 lb (302 kg)
838 lb (380 kg)
OBSERVE ATTENTION LABEL
ON OVEN FOR
AREA TO AVOID
WITH LIFTING FORK
.