Operation and Care Manual #8452/53/55 6
ITEM
POWER SWITCH (FRYER-OFF-FILTER)
Fryer position turns on the ventilator,
power light and the blower for 10 seconds.
If, within 10 seconds, there is sufficient air
flow for proper operation, the ventilator power
light will remain on and the fryer will operate.
If after 10 seconds, there is not sufficient air
flow for proper operation, the blower and
ventilator power light will turn off. The
service required light will will turn on and the
fryer will not operate.
The power switch must be turned off to recycle
power before the fryer can be operated.
ITEM
VENTILATOR POWER LIGHT (GREEN)
The ventilator power light turns on when the
fryer power switch is on and air flow has been
proven. Normally the ventilator light will be
the only light illuminated on the ventilator
warning light panel.
ITEM
CHECK FILTERS LIGHT (AMBER)
The check filters light turns on when the grease
and/or air filter are not properly installed.
When the check filters light is on, the fryer
heating element(s) is de-activated and the fryer
will not heat.
If the check filters light illuminates, check both
the grease baffle and HEPA filter for proper
installation. Always replace the HEPA filter
and charcoal filters at the same time.
When the check filters light is off, the fryer will
operate normally.
ITEM
REPLACE FILTER LIGHT (AMBER)
The replace filter light will turn on
when the HEPA and charcoal air
filters are due for replacement. The fryer will
still operate normally, but the air filter must be
changed in a timely manner or it will clog, the
service required light will turn on, and the
fryer will shut down until the air filters have
been replaced.
ITEM
SERVICE REQUIRED LIGHT (RED)
If the service required light illuminates, the
fryer is shut down until the underlying
clogged filter situation has been corrected.
Normally, replacing both the HEPA filter and
the charcoal filter will remedy the condition.
Reset the unit by turing the power switch to
OFF and then back to Fryer.
SERVICE POWER FAILURE
If the shutdown is caused by a service power
failure, the fryer can be restarted by cycling the
power switch to OFF and then ON.
CONTROLS • FUNCTIONS • OPERATION