Gas Convection Oven - Electronic Control
Pg. 6.
GAS SUPPLY & INSTALLATION
GAS REQUIREMENTS
The gas inlet is located at the back of the oven.
Code requires the installation of a manual gas
shutoff valve to be installed in the gas line ahead
of the oven. This oven is also equipped with fixed
burner orifices determined by the elevation
specified as the initial installation location.
The oven is furnished with a regulator integral to
the operation of the gas solenoid valve and may
not require an additional external regulator. To
ensure safe and proper operation, the gas
pressure regulator installed in the oven is
required for use with both natural gas and
propane. If the connected pressure exceeds 14.0"
W.C. (3.48 kPa), a step-down regulator is
required. A step-down regulator is not the
responsibility of the manufacturer.
Use an approved pipe sealant at all connections.
Do not use Teflon® tape. Gas supply connections
and pipe joint compound must be resistant to the
action of propane gases. Pipes must be clean, free
of obstructions and pipe joint compound.
GAS CONNECTION
In the U.S.A., installation must conform to
local codes or, in the absence of local codes,
with the current edition of the National Fuel
Gas Code, NFPA-54 and ANSI Z223.1-1980
(latest edition). In Canada, installation must
be in accordance with local codes,
CAN/CGA-B149.1, Installation for Natural Gas
Burning Appliances and Equipment (latest
edition) or CAN/CGA-B149.2 Installation for
Propane Burning Appliances and Equipment
(latest edition).
The inlet supply line must be properly sized
to accommodate all individual appliances
simultaneously used on the same line but
must never be smaller than 3/4" NPT.
INCORRECT CORRECT
A
B
C
D
E
F
G
H
GAS INTAKE
A-G Installation elbow
B Wall Valve
C-D Three-piece union fitting
(minimum 1 per installation)
E-F End connector for the flexible tube
H Marking line
D A N G E R
Installation, air adjustment and/or
s
ervice work must be in accordance
with all local codes and must be
performed by a certified service
technician qualified to work on
gas appliances.